Monday, February 22, 2016

Showa 6110PF EBT Biodegradable Nitrile Gloves



HOW IT WORKS:
When disposed in landfills, microorganisms consume, metabolize and break down EBT materials into three natural compounds— organic soil, methane and carbon dioxide. This creates fertilizer, leaving zero waste behind.

WHERE IT GOES
EBT requires biologically active landfills for biodegradation. Which means gloves with EBT cannot even begin to biodegrade prior to disposal. These abilities have been validated by independent certified laboratories using ASTM International test methods (ASTM D5511).

WHY IT’S IMPORTANT:
Consider the number of disposable gloves used every day in hospitals, offices, schools, warehouses, labs and even our own homes. The numbers are astronomical. With EBT, we help preserve the planet by accelerating each glove’s bio-degradation process by up to 100 years*. And every glove makes a difference.
*depending on climate and location of landfill

Showa 6110PF EBT Biodegradable Nitrile Gloves

Crafted with SHOWA’s revolutionary Eco Best Technology® (EBT), this biodegradable 4-mil (0,10mm), nitrile disposable glove delivers unmatched comfort, dexterity and performance across a range of applications.
  • 100% nitrile with Eco Best Technology®
  • 4 mil (0,10mm) thick
  • 9.5 inches (240mm) long
  • Zero natural rubber latex proteins
  • Powder free
  • Rolled cuff
  • Performs same as non-EBT nitrile disposable gloves
  • 100% biodegradable
  • Decreased risk of allergies
  • High performance of protection
  • Second-skin fit & feel

  • Quantity: 1 Case = 1000 Gloves = 10 Boxes of 100 Gloves
  • Liner: Disposable
  • Coating/Polymer: Biodegradable Nitrile
  • Grip: Smooth
  • Color: Green
  • Length 9.5"
  • Sizes:
    • 5-6 = Extra Small (XS)
    • 6-7 = Small (S)
    • 7-8 = Medium (M)
    • 8-9 = Large (L)
    • 9-10 = Extra Large (XL)
    • 10-11 = 2X-Large (XXL)
Learn more about Showa EBT gloves here.

Thursday, February 18, 2016

Enpac 4064-ECO-D ECO-Efficient: 4-Drum Hardcover & Spill Pallet W/Drain - Green


ENPAC® is proud to present its newest, greenest, and most economical product line ever! Saving the earth and your wallet, these World’s Best Sellers are now offered in ENPAC® green made from up to 100% Recycled material! Not only will you meet regulations, but you will exceed your expectations of earth-friendly containment by using this official ENPAC® ECO-Efficient Hardcover & Spillpallet w/Drain! Ideal for indoor/outdoor storage of up to four (4) 55-gallon drums. Roll-top design allows for use in limited space or next to buildings where swing-open doors could be a problem. Dual-sided/ rear loadable lockable door! Removable grates for easy cleaning. Optional ramp, ramp extender and drain. Some assembly required.

Link to read more: https://www.industrialsafety.com/Enpac-4064-ECO-D-p/enpac-4064-eco-d.htm

Sunday, February 14, 2016

Macurco CM-6 Carbon Monoxide CO (Low Voltage) Fixed Gas Detector Controller Transducer 70-0715-6500-9

Macurco CM-6 Carbon Monoxide CO (Low Voltage) Fixed Gas Detector Controller Transducer 70-0715-6500-9

Carbon Monoxide Detection and Control
The Macurco CM-6 is a low voltage, dual relay Carbon Monoxide (CO) detector, controller and transducer.
The CM-6 has selectable 4-20 mA output, buzzer and digital display options. It is an electronic detection
system used to measure the concentration of CO and provide feedback and automatic exhaust fan or valve
control to help reduce CO concentrations in parking garages, maintenance facilities or other commercial
applications. The CM-6 is a low level meter capable of displaying from 0-200 ppm of Carbon monoxide.

Selectable options include:
• Fan relay actuation: selectable at 15, 25, 35 (default), 50 or 100 ppm CO
• Output: Fan relay, Alarm relay and 4-20mA current loop
• Controls: Digital display (0-200 ppm), buzzer, fan delay, fan minimum runtime
Installation
• Mounts on a standard 4” x 4” electrical box
• 5 A SPDT fan relay controls valves, louvers or exhaust fans
• 0.5 A N.O. or N.C alarm relay connects to warning devices or control panels
• 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel
• Factory calibrated

Other Features
• Supervised system design: detector problem will cause the fan & alarm relay to activate
• Optional calibration kit allows the CM-6 to be field tested and calibrated
• ETL Listed to UL 61010-1, CAN/CSA C22.2 No 61010-1, LADBS Approved

• Power: 3 W (max) from 12 to 24 VAC or 12 to 32 VDC
• Current @ 24 VDC: 75 mA in alarm, 50 mA fan relay on and 23 mA stand by
• Shipping Weight: 1 pound (0.45 kg)
• Size: 4 1/2 x 4 x 2 1/8 in. (11.4 X 10.2 X 5.4 cm)
• Color: Dark gray
• Connections: plugs/terminals
• Mounting Box: (not included) 4x4 electrical
• Fan Relay: 5 A, 240 VAC, pilot duty, SPDT, latching or non-latching
• Fan Relay Actuation: selectable at “dIS” (disabled), 15 ppm, 25 ppm,
35 ppm (default), 50 ppm or 100 ppm
• Fan Delay Settings: 0, 1, 3 (default), 5 and 10 minutes
• Fan Relay Minimum Runtime Settings: 0 (default), 3, 5, 10 or 15 minutes
• Alarm Relay: 0.5A 120 V, 60 VA
• Alarm Relay Actuation: selectable N.O. default or N.C.
• Alarm Relay Settings: dIS, 50 ppm, 100 ppm, 150 ppm and 200 ppm (default)
• Current Loop: 4-20 mA for 0-200 ppm
• Operating Environment: 0°F to 125° F (-18°C to 52°C),10 to 90% RH non-condensing

Location
The unit typically covers about 5,000 sq.ft. (465 square meters) in a parking garage or similar application and
900 sq.ft. (84 square meters) in a residential or office type application. The coverage depends on air movement
within the room or facility. Do not mount the CM-6 in a corner. The detector may be installed on either a ceiling or
a wall. If installed on a peaked, gabled, or sloped ceiling, it should be located about 3 feet (1 meter) from the
highest point. Normally, the unit is mounted about 5 feet (1.5m) above the floor (normal breathing zone), in a
central area where air movement is generally good. Additional detectors may be needed near any areas where
people work or where the air is stagnant.